The controller does not work after powered on |
|
|
Can not measure, display "A/D error". |
|
|
Can not measure, display "sigl error" |
|
|
Can not measure, display "over range" |
|
|
Not stable in manual and automatic mode |
-
Tension sensing roller out of roundness, bearing damaged, roller bended.
-
Bad clutch/brake or driver
-
Signal fails or incorrect calibration
|
|
Stable in manual mode but not stable in automatic mode |
-
Bad type of tension sensor.
-
Bad type of clutch, brake or driver.
-
Bad value for Prop. Band[05], Inte. Time[06] and Dead Band[07]
|
-
Use the appropriate sensor and recalibrate
-
Use the appropriate drive unit
-
Alter the value of these three parameters
|
Incorrect calculation of radius |
-
The setting of radius calc related parameter is incorrect.
-
Wrong proximity switch/encoder.
-
proxmity switch/encoder damaged or incorrect connection.
|
-
Set proper values for the radius calc. related parameters.
-
Use proximity switch or encoder with NPN signal
-
Check connection or replace new proximity switch or encoder
|
No output |
-
Output has been turned off
-
Output short-circuit protection
-
Incorrect connection of Reel A and Reel B
|
-
Press the OUTPUT ON/OFF switch to turn on
-
Switch power off, switch on after 30 seconds
-
Connect the drive unit properly
|
The keys and digital knob do not work |
Keypad has been locked |
Check the Lock indicator, if Lock is on, the keypad is locked. Press LOCK key to
unlock. |
The controller does not start after MC1 is on |
|
-
Disable the Sync. Mode[39] function.
-
The proximity switch must be mounted on the main reel while enabled and set right
value for Start Freq.[03].
-
Set right value for Action Mode[38].
|
Can't switch to automatic mode |
|
-
Check sensor, connections, parameters and recalibrate until getting the correct
measurement
-
Keypad locked, press LOCK key to unlock.
|
Tension too high or too low after restarting |
|
|
Setting tension(SV) changes after switching from manual mode to automatic mode |
While switching the controller from manual mode to automatic mode, the measured
tension before switching will be used as the setting tension for automatic control |
This is normal, it makes the smooth transition. |